Services

Pipeline Integrity

IntegrityTechCorr is an industry leader in Pipeline Integrity Management. Considering the nature of the pipeline infrastructure in North America and the recent changes to the regulations, the questions that are on all operators minds are:

  • “How can I manage my pipelines in a cost effective manner to support my company’s objectives for integrity and safety?”
  • “How can I ensure that my pipeline is and remains fit for purpose?”
  • “What program(s) should I use to effectively set my reassessment intervals?”
  • “How will I be able to comply with the changing regulatory environment?”

With the use of sound technology and proper planning, Pipeline Integrity CAN be managed and fitness for purpose can be determined, repairs made and mitigation practices established that will ensure a safety of your assets. TechCorr is one of the few companies able to provide a truly integrated approach to pipeline integrity by offering the following services:

Back to Top Consulting Services

Whether you choose a prescriptive or a non-prescriptive country standard to meet regulatory compliance requirements your company will be required to plan and budget for this process. Gathering specific pipeline integrity data, knowing what data to gather, how to verify it and assess the risks on a pipe segment by segment basis will be required during the pre and post assessment phases of any pipeline integrity project. TechCorr is an industry leader in providing pipeline integrity people, process and technology to meet the toughest regulatory problems.

Pre/Post Assessment Services include but are not limited to the following:

  • Project Management
  • Preliminary country specific regulatory audits
  • Data gathering and verification
  • Data input
  • Data interpretation & analysis
  • Risk analysis & assessment
  • In-Line inspection planning & management
  • Direct Assessment (DA) planning & management
  • Mechanical damage assessments (ASME B31g, RSTRENG, etc.)
  • Pipeline remediation and repair planning & management
  • Integrity Management Plans (IMPs)
  • Dig Prioritizing
  • Root Cause Analysis
  • Fitness for Service

Back to Top Data Integration

  • Pipeline Information Control System
  • Alignment Sheet Generator
  • Cathodic Protection Data Management


Back to Top Cathodic Protection & Surveys

TechCorr provides the complete range of indirect inspection technologies and services to meet any pipeline integrity requirement. Indirect inspection includes aboveground surveys used to define the severity of coating faults, the effectiveness of the CP System and whether there are active / inactive corrosion features along the pipeline. To meet Direct Assessment (DA) standards, two or more survey techniques (I.e. technologies) must be used to over the entire pipeline segment with the resulting data aligned and analyzed to develop an accurate picture the potential for corrosion.

The proper tools must be utilized in above ground pipeline surveys to ensure that the most accurate data acquisition takes place to support any regulatory or industry standard. These surveys include Close Interval Potential (CIPS), Direct Current Voltage Gradient (DCVG) and Current Attenuation (C-Scan & PCM) and GPS.

TechCorr follows the proposed NACE standard for data acquisition for Above Ground Coating Evaluation and utilized the DA Meter to combine the datasets for an aligned presentation. TechCorr offers our clients the full range of capability associated with the PICS application suite by Baker Hughes as our preferred survey data analysis tool.

Back to Top Direct Examination

TechCorr provides the complete range of Direct Examination technologies and services to meet any pipeline integrity requirement. Direct Examination requires exposure of the pipe to quantify and assess any and all defects found.

Direct Examination utilizes indirect inspection data to prioritize sites for excavation. A direct examination of the pipeline surface is then carried out using a systematic forensic approach to understand why corrosion occurred at a specific location and the extent of such damage. This step might include investigating why the coating holiday occurred, understanding PH at the coating surface and the composition of any liquids identified within the coating holiday, the pipe to soil potentials, the soil resistivity at depth, to calculate the remaining strength utilizing B31G or RSTRENG criteria and finally a microbiological evaluation of soils and fluids present. Additionally, during the direct examination phase, a detailed evaluation of the anomalies utilizing ultrasonic mapping techniques to better understand the extent of damage may be performed. Finally, in the event the defects are occurring in continuous or clustered patterns, Guided Wave Ultrasonics might be used to create a larger “Foot Print” to determine the extent of the corrosion beyond the excavation.

Direct examination Services ( also known as “in-the-ditch” services include but are not limited to the following:

  • Traditional NDE
    • Magnetic particle
    • Liquid/Dye penetrant
    • Ultrasonic (hand held)

  • Environmental
    • Soils analysis (Ph, MIC, etc.)

  • Advanced NDE
    • AUT inspection and mapping
    • Laser inspection and mapping

  • Long Range Guided Wave Ultrasonic
  • Alternating Current Field Measurement


        
Back to Top In-Direct Inspection Services

  • General Surveys
    • Pipeline GPS survey
    • Pipeline depth of cover survey

  • Cathodic Protection (CP) Surveys
    • Pipe-to-soil potential survey
    • Close Interval Potential Survey (CIPS)
    • Hot spot survey
    • Electrical isolation tests
    • Bonds measurement
    • Rectifier inspection
    • Ground beds and connections
    • Casings

  • Coating Surveys
    • Alternating current attenuation
      • Pipeline Current Mapper (PCM)
      • C-SCAN

  • Direct Current Voltage Gradient survey (DCVG)

Knowing exactly where your pipeline is and the depth of cover are the first steps in an accurate survey. Following the above ground surveys, locating the exact location for excavation can save time and money.
TechCorr integrates sub-meter accuracy GPS when performing all survey work from simple test station readings to complete real-time data acquisition while surveying pipelines for coating holidays or cathodic protection system monitoring.

TechCorr utilizes the Trimble’s XRP system w/ the Terra-Sync and Pathfinder Office software for post processing which provides the highest accuracy down to the sub-meter level.

 
Home | Copyright